GALILEO PLUS RT

On-line 1-phase RT UPS 1000-3000 VA

Galileo Plus RT is an on‑line double conversion single phase UPS that can be used in both tower and rack configurations thanks to its reversible design. Galileo Plus RT UPS is ideal for small and medium businesses, networks and servers, delivering a rated power of 1000, 2000 and 3000 VA.

  • Available in a flexible Rack/Tower 2U design allowing the unit to be configured for rack-mount or free standing applications.
  • User-friendly reversable display to monitor and control UPS and system parameters, battery charge levels and potential faults.
  • Additional matching battery cabinets to increase the backup time of the UPS.
  • On-Line double conversion technology protects from all power failures for maximum uptime.
  • Active harmonic power quality control with THD <3% for maximum compatibility with sources.
  • Matching battery extension box allowing additional autonomy time to be quickly added.
  • Automatic self-test and advanced battery management maximizing battery performance and extending battery life.
  • Borri user-friendly UPS management software free downloadable at Borri website. Borri management software is available for Microsoft and Linux operating systems, providing UPS management with alerts upon main power failures and system shutdown notification via SMS and email.
  • Input Power Factor 0.99 and THD <3%.
  • Audible alarm alerts upon utility power and UPS status change.
  • Smart cooling system ensuring further energy savings.
  • Remote emergency power off for immediate UPS shutdown.
  • USB communication port providing UPS management.
  • One slot auto-sensing for communication cards.
  • Cold start for powering loads when the mains are not available.
  • Six output receptacles (6 IEC C13) for models from 1000 to 3000 VA versions. Additional output receptacle 1 IEC C19 for model 3000 VA version.

Tech Specs

GALILEO PLUS RT: on-line 1-phase RT UPS 1000-3000 VA

Rating (VA) 1000* 2000* 3000*
Nominal power (W) 900 1800 2700
UPS dimensions WxDxH (mm) (2U)88x405x440 (2U)88x600x440 (2U)88x600x440
Battery cabinet dimensions WxDxH (mm) (4U)176x405x440 (2U)88x600x440 (2U)88x600x440
UPS weight (kg) 12 29.5 30

Input

Connection type IEC 320-C14 IEC 320-C20
Nominal voltage 230 Vac 1-phase
Voltage range 180 to 300 Vac at full load
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <3%

Output

Connection type 6 IEC C13 6 IEC C13 + 1 IEC C19
Nominal voltage 230 Vac +/-1% 1-phase
Frequency 50/60 Hz
Power factor 0.9
Overload capability 105% continuous, 120% for 30 seconds,
150% for 10 seconds
Mode of operation On-line, Eco-mode
Classification by IEC/EN 62040-3 VFI-SS-11

Battery

Autonomy time
internal battery
(min)
50% load 15 16 12
100% load 5 5 4

*Rack/Tower

Connectivity and function extensions

Front panel Display LCD, status LED, function keys
Communication Included: USB, EPO, RS232.
Optional: dry contact card, SNMP card.
Compatible platforms: Windows, Linux

Environmental

Operating temperature range 0°C to +40°C
Altitude (AMSL) <1000 m without power reduction, > 1000 m with reduction of 1% per 100 m
Audible noise at 1 m (dBA) <50

Standards and certifications

Quality assurance,
environment, health and safety
ISO 9001:2015, ISO 14001:2015, BS OHSAS 18001:2007
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Test and performance IEC/EN 62040-3
Marking CE
TOP