Our customized solutions are designed to withstand harsh conditions in typical marine environments. Vibrations, shocks, high temperatures and cramped spaces are all key issues to be considered when deploying a power protection system onboard.
Vessels need to be fully operational and at the highest performance levels during all their journey across seas and oceans. Any interruption, blackout and other disturbances can put at risk onboard equipment and passengers’ safety.
Borri offers a complete range of products specifically tailored for marine applications. Depending on the kind of vessel and requirements, we provide the most robust conventional or modular AC and DC systems.
Borri engineered and ruggedized UPS solutions are designed to protect ship critical equipment and essential systems onboard that need to keep fully operational even in case of power interruption.
Borri rectifiers securely provide supply to DC powered loads as well as battery charging, whether onshore or offshore. Flexible solutions that can be used to recharge ships’ batteries and to provide reliable energy to DC vital and auxiliary services.
Borri product range includes both shore-to-ship and ship-to-shore converters, which guarantee reliable power supply to docked ships. Environmental footprint and cost savings are critical issues for port authorities and shipowners. Power converters reduce emissions and fuel costs when ships dock in ports. Borri converters regulate the grid power supply to the appropriate ship voltage and frequency.
AC and DC systems installed in a 67.000-ton, 1.200-passenger cruise ship to protect safety systems and onboard critical applications. Borri has provided UPS systems from 5 to 200 kVA and rectifiers from 40 to 90 Amp and 24-110 Vdc. Vin=690 Vac / Vout=220 Vac. IP 22 protection degree. Battery cabinet integrated.
IP 44 frequency converter 200 kVA with input range 170-520 Vac 50/60 Hz and output 400 Vac 50 Hz. Double input configuration to allow converter's power supply from 2 different docks. A Seamless Control Box manages the converter's synchroni zation with up to 4 generators.
DC systems installed onshore providing submarine auxiliary services and battery charging. Vout = 165-605 Vdc adjustable (optional up to 900 Vdc) / Aout = 0-400 A adjustable (optional up to 2,000 A). IP 44 protection degree and AISI 316L cabinet. Optional rectifier discharger.
30 x AC UPS 30 kVA
DC UPS 50 A 450 Vac/110 Vdc, AC UPS 100kVA
UPS 75 kVA, separated distribution and batteries
Dual AC UPS 40 kVA, 110 Vac, with common distribution board
Dual AC UPS 32 kVA, 440 Vac 3-phase input / 220 Vac 1-phase output
AC UPS 200 kVA and 350 kVA, 400/230 Vac, DC UPS 110 Vdc, 92,5 kW and 400 V