E8031/E8033 ECS

Emergency Central Systems
3/1- and 3/3-phase 10-20 kVA

Borri E8000 ECS Emergency Central Systems have been designed in compliance to the international EN 50171 standard, supplying uninterrupted quality power to emergency and safety installations, such as:

  • Emergency lighting.
  • Automatic fire detection and extinguishing equipment.
  • Smoke extraction systems.
  • Carbon monoxide warning systems.
  • Paging systems and signaling safety installations.
  • Special safety installations related to high-risk areas.
  • Continuous savings with Green Conversion technology, providing high efficiency and UPS components’ life extension.
  • Small footprint thanks to a compact transformer free design.
  • Fast installation and monitoring: user-friendly design with built-in LCD display.
  • Easy access for fast maintenance and low MTTR.
  • 120% permanent power overload capability.
  • Batteries with 10 years life expectancy.
  • Acid proof battery cabinets and racks.
  • Battery polarity reversal protection.
  • Deep discharge protection.
  • Short circuit protection.
  • Battery charger to recharge battery to provide 80% autonomy within 12 hours.
  • Battery charger temperature compensation.
  • IP20 metal enclosure as per EN60598-1.

Tech Specs

E8031/E8033 ECS : Emergency Central Systems 3/1 and 3/3-phase 10-20 kVA

Rating (kVA) 10 15 20
Nominal power (kW) 9 13.5 18
Nominal power as per EN 50171 (kW) 7.5 11.3 15
UPS dimensions
WxDxH (mm)
450x670x1200
UPS weight (kg) 100 110 110
Battery External, 360 to 372 cells, VRLA (other options)

Input

Connection type 3/1-phase units: hardwired 4w (rectifier), 2w (bypass)
3/3-phase units: hardwired 4w (separate bypass input available on request)
Nominal voltage 400 Vac 3-phase with neutral (rectifier)
220/230/240 Vac (3/1-phase bypass)
Voltage tolerance -20%, +15% (rectifier) ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.98
Current distortion (THDi) <4%

Output

Connection type 3/1-phase units: hardwired 2w
3/3-phase units: hardwired 4w
Nominal voltage 3/1-phase units: 220/230/240 Vac 1-phase
3/3-phase units: 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1%; dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 0.9, without power derating
Overload capacity* 120% continuous; 150% for 10 min;
Efficiency (AC/AC)** Up to 98%
Classification as per IEC/EN 62040-3 VFI-SS-11

*as per EN 50171 **as per IEC/EN 62040-3

Connectivity and function extensions

Front panel Graphic display, mimic LED panel and keyboard, local EPO
Remote communication Included: serial RS232 and USB; terminal block for battery breaker auxiliary contact.
Optional: input terminal block (remote emergency power off, external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.); SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485), from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Optional features Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; load-sync for single UPS; AO+EO mode kit; separate input for rectifier and bypass line (for 3-phase output models); parallel kit; other options on request

System

Protection degree IP 20
Colour RAL 7016
Installation layout 10 cm wall-gap, side by side installation allowed
Accessibility Front and top access, bottom cable entry

Environmental

Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <52

Standards and certifications

CPSS EN 50171
Quality assurance,
environment, health and safety
ISO 9001, ISO 14001, ISO 45001
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
TOP